Output Data List

The ZG series can output three types of data (measurement values, judgment values and profile
data) to external devices. All output data on the ZG series can be obtained by serial communication.
Measurement value (result for each individual task)
Output path
Controller analog output The task is output as an analog value.
Parallel Output Unit
Serial communication
Profile
Output path
Controller I/O cable
Parallel Output Unit
Serial communication
Judgment value (result for each individual task)
Output path
Controller I/O cable
Parallel Output Unit
Serial communication
Note
Either of the following methods can be selected for acquiring output data by serial
communication:
• Command response method
• Auto output method (Data is output automatically when trigger measurement ends.)
Communication Method p.127
110
Output Data List
Description
The task is output in 16-bit binary format.
The results of all tasks or each individual task are output as ASCII code.
Description
(No output)
(No output)
Profile data of 631 points is output as either ASCII code or in binary format.
Description
The overall judgment of all tasks is output.
The following output is performed on registered tasks:
ALL PASS:This output is turned ON when all judgment results are OK.
NG:
This output turns ON when even one measurement result is NG.
ERROR: This error turns ON when there is even one measurement
error. (ERROR has higher priority over NG.)
Judgment values are output for each individual task.
TASK1: HIGH/PASS/LOW/ERROR
TASK2: HIGH/PASS/LOW/ERROR
:
TASK7: HIGH/PASS/LOW/ERROR
TASK8: HIGH/PASS/LOW/ERROR
Results are output for each individual task.
ZG User's Manual