Setting item
Edge width
Max.
Edge width
Min.
2
Edge width
Ave.
Lost width
count
* dist (X_MAX,Y_MAX) = sqrt (X_MAX*X_MAX+Y_MAX*Y_MAX)

Output Parameters (Scan Edge Width)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
2.
Specify each of the following items.
Setting item
Output
Coordinates
Calibration
Reflect to
overall
judgement
152
Scan Edge Width
Set value
0 to dist
Specify the upper and lower limits of the maximum width judged
(X_MAX,Y_MAX)
to be OK.
0 to dist
Specify the upper and lower limits of the minimum width judged
(X_MAX,Y_MAX)
to be OK.
0 to dist
Specify the upper and lower limits of the average width judged to
(X_MAX,Y_MAX)
be OK.
Specify the upper and lower limits of the lost width count judged
0 to 100
to be OK.
Set value
[factory
default]
[After
As measurement results, select whether to output coordinate values
scroll]
to external devices before or after the position deflection correction is
Before
applied.
scroll
Select whether to reflect the calibration in the values output to the
[OFF]
external device as measurement results.
ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
[ON]
Enables choosing whether or not the judgement results of this
OFF
processing unit is reflected in the scene overall judgement.