27.4.10 CNC Side Settings

1
System configuration
The following shows the example of the system configuration when using the CNC monitor function.
2
Parameter setting
Set parameters related to Ethernet with MELSEC's peripheral devices in the same way as
parameter setting of MELSEC CPU, and write them on CNC by PC.
(1) Network parameter setting
Set the network parameters by peripheral device and write them on CNC. An example of parameter
setting by GPPW is as follows.
Set the first I/O No. as follows according to the expansion slot to which the unit is inserted.
(a) Unit No.
Slot
Start I/O No.
position
EXT1
0200
EXT2
0280
EXT3
0300
27 - 80
27.4 Ethernet Connection
27.4.10 CNC Side Settings
<CNC-2>
N/W No.
:239
PLC No.
:3
IP address:192.168.1.3
Ethernet(192.168.1.xx)
<CNC-1>
[Communication with GOT]
N/W No.
PLC No.
IP address:192.168.1.2
[When mounted in EXT1 and EXT2] [When mounted in EXT1 and EXT3] [When mounted in EXT2 and EXT3]
EXT2
EXT1
Unit2
Unit2
Unit1
[When mounted in EXT1 only]
EXT1
Unit1
:239
:2
Mounting position of extension unit
EXT3
EXT1
Unit1
[When mounted in EXT2 only]
EXT2
Unit1
<GOT>
N/W No.
:1
PLC No.
:1
IP address:192.168.1.1
EXT2
EXT3
Unit2
Unit1
[When mounted in EXT3 only]
EXT3
Unit1

Hide quick links: