1
Information Center Configuration Commands
The information center now supports to add the UTC time zone in the time stamp of the output
information. See
Information Center Configuration Commands
display channel
Syntax
display channel [ channel-number | channel-name ]
View
Any view
Parameters
channel-number: Channel number, ranging from 0 to 9, corresponding to the 10 channels of the system.
channel-name: Channel name, by default, the name of channel 0 to channel 9 is (in turn) console,
monitor, loghost, trapbuffer, logbuffer, snmpagent, channel6, channel7, channel8, channel9.
Description
Use the display channel command to display the settings of an information channel.
If no argument is specified in the command, the settings of all channels are displayed.
Examples
# Display the settings of information channel 0.
<Sysname> display channel 0
channel number:0, channel name:console
MODU_ID
NAME
ffff0000 default
display info-center
Syntax
display info-center [ unit unit-id ]
info-center timestamp utc
ENABLE LOG_LEVEL
Y
warning
for details.
ENABLE TRAP_LEVEL
Y
debugging
1-1
ENABLE DEBUG_LEVEL
Y
debugging