SKP-SR for BS2000 operation
14.3.2 Automatic system operation via ATOP
The ATOP is connected to the SKP-SR serial ports. One serial connection to the SKP-SR
is required for each system to be monitored.
The monitor script must first control the SKP-SR login before logging in via LAN to the
system login which provides access to the console that is to be monitored (e.g. cons0 for
the BS2000 console).
14.3.3 Use as NTP time server
The SKP-SR can be used as an NTP time server for the SMC if a TSP radio clock 3919 or
Global Time Server 3920 is connected to the SKP-SR and configured (for information on
configuration, see the manual
410
"SINIX-2000
V8.0/V8.1/V8.5" [19]).
Appendix
U41272-J-Z385-3-76