X2000 messages
IODE062
CHPID xx was already online
Meaning
The module was already in the online state at the time of the MSSF call CHPOFF - vary
channel path online.
Response
No maintenance response is required.
IODE063
CHPID xx vary online rejected: hardware error
Meaning
The MSSF call CHPON - vary channel path online was rejected because of the
presence of a hardware error. Appropriate error handling is performed for the hardware
error.
Response
For information on error handling, see the messages relating to module stop error handling
(
IODE021, IODE022
IODE064
CHPID xx vary online rejected: busy
Meaning
The MSSF call CHPON - vary channel path online was rejected because error
handling was simultaneously active. BS2000 automatically repeats the MSSF call. This
message is for diagnostic purposes and is output only if the service engineer specifies this
explicitly.
Response
For information on error handling, see the messages relating to module stop error handling
(IODE021, IODE022).
IODE065
CHPID xx vary online rejected: CHPID invalid
Meaning
The MSSF call CHPON - vary channel path online was rejected because the specified
CHPID is invalid.
Response
Check the configuration.