Fujitsu Siemens Computers SX series User Manual page 380

Sx150 business server
Table of Contents

Advertisement

X2000 channel connection error messages
..SS003
channel initialization timed out
Meaning
Software error: The cipl script was aborted because initialization of the channel system
was not terminated within the predefined period (10 minutes).
..SS101
device <dev> occupied by '<proc>' PID: <pid>
Meaning
Reservation error: The called process is aborted because the device <dev> has been
reserved by the process <proc> with the ID <pid>.
If a semaphore cannot be reserved even though the competing process is subsequently
terminated, then <proc> is an empty string and multiple <pids> may be displayed.
Example: device /dev/apc/cha1 occupied by '' PID: 213 430 431
The message ...I703 cannot reserve semaphore (see
page
364) is also output.
Response
It is necessary to wait until the other process has released the semaphore.
..SS201
device occupied or semaphore reserved
Meaning
Reservation error: In the case of the cdebug script, this error message indicates that the
semaphore could not be reserved since it is occupied by a competing process. The
occupant is not identified.
Response
Close the current window, wait for the semaphore to be released and then open the window
again.
..SS203
unconfigurable channel(s) 8E, 8F and/or FF detected
Meaning
The cdebug script identifies one or more channels for which the CHPID 8E (configuration
of virtual consoles), 8F (logout device) and/or FF (identifier for invalid CHPIDs) has been
allocated.
380
X2000 messages
section "HWI messages" on
U41272-J-Z385-3-76