IOD messages
IODE0E0
Error Code xx: Error detected by IOD-Firmware
Meaning
The IOD has detected an internal error and has reset the channel subsystem. All installed
components of the channel subsystem are initialized and started.
Response
The error has been eliminated for the present by the error handling operation. There is
generally no hardware error present when the IOD detects such an internal error.
Consequently, the result of the analysis of the corresponding logouts does not output any
hardware errors or instructions for replacement. Inform the Support Center.
IODE0E1
Subchannel mark timeout
Meaning
This message is output in addition to the message IODE0E0.
Response
See the message IODE0E0.
IODE0E2
aaaaaaaa: xxxxxxxx xxxxxxxx xxxxxxxx xxxxxxxx
Meaning
This message is output in addition to the message IODE0E0.
Response
See the message IODE0E0.
IODF004
IORSF Error: DEV=xxxx invalidated - CHPID not configured
Meaning
A device is identified as invalid because no channel connection is present.
Response
Regenerate IORSF.
IODF005
IORSF Error: DEV=xxxx invalidated - connected to different PCI-buses
Meaning
A device is identified as invalid because the Multipath mode can only be operated within
a UHPS.
Response
Regenerate IORSF.
IODF006
TOO MANY CONTROL UNITS (CUCR) ASSIGNED
Meaning
Content error in IORSF.
Response
Regenerate IORSF.
356
X2000 messages
U41272-J-Z385-3-76