X2000 messages
KVP0014
STATION (&00) REJECTED BY SYSTEM: CONSOLE (&01) IS ALREADY ASSIGNED
&00 = User ID, &01 = Mnemonic name of console
Meaning
Another station is already logged on at the BS2000 system with the specified mnemonic
console name. This mnemonic console name is not currently available.
KVP0019
SYSTEM IS NOT READY FOR INPUT
Meaning
BS2000 is not active, the IPL has not terminated or still has to be started. The message is
output if console I/O traffic (read path) is disrupted (system/hardware error).
Response
You must wait for the end of the current IPL or perform a new IPL.
KVP0020
SYSTEM INPUT FROM CONSOLE (&00) TIMED OUT
&00 = Mnemonic name of console
Meaning
BS2000 has not accepted an input.
Response
Repeat the input. If it is rejected again, perform a new IPL.
KVP0041
COMMENCING BS2000 SHUTDOWN - (&00)
&00 = Explanatory text
Meaning
An extraordinary BS2000 shutdown has been initiated. The text specifies the cause.
KVP0042
COMMENCING SYSTEM SHUTDOWN - STOP OF KVP IN MAXIMUM (&00) MINUTES
&00 = Maximum wait time
Meaning
BS2000 is termited. KVP is then terminated. UNIX is terminated at the latest on expiry of
the specified time.
This message may also be issued if an environment fault has occurred.
Fan fault
Temperature monitoring
Power supply fault
Response
In the case of an environment fault: identify and eliminate the cause. If necessary, inform
the service staff.