IOD0999
IOD_Vxx SL=mmm *** IOD ABNORMAL END ***
IOD0999
*** ERROR CODE=modyyy *** START IMPL!
Meaning
IOD has detected an error and terminated the system run. On the next system start (IMPL),
an IOHDUMP will be generated and saved in the directory /var/opt/SMAW/X2000/dump/.
IOD0999
*** ERROR CODE=CPI015 *** START IMPL!
Meaning
The HAL has not responded to the initialization message within 10 seconds.
Response
Identify the cause of the error and repeat the IMPL or execute bs2init 0 and bs2init 1.
IOD0999
*** ERROR CODE=CPI018 *** START IMPL!
Meaning
The HAL has not responded to the device configuration message within 10 seconds.
Response
Identify the cause of the error and repeat the IMPL or execute bs2init 0 and bs2init 1.
IOD0999
*** ERROR CODE=CPI021 *** START IMPL!
Meaning
The HAL has not responded to the DUMP address message within 10 seconds.
Response
Identify the cause of the error and repeat the IMPL or execute bs2init 0 and bs2init 1.
IOD0999
*** ERROR CODE=CPI022 *** START IMPL!
Meaning
The HAL has not responded to the vector table message within 10 seconds.
Response
Identify the cause of the error and repeat the IMPL or execute bs2init 0 and bs2init 1.
IOD0999
*** ERROR CODE=CPI089 *** START IMPL!
Meaning
The number of bus devices is smaller than 3 or greater than 32768.
Response
Check the BU device configuration, make any necessary changes and repeat the IMPL or
execute bs2init 0 and bs2init 1.