X2000 messages
IOD0999
*** ERROR CODE=IPL005 *** START IMPL!
Meaning
The RMAssist has not responded to an IOD message within 10 seconds.
Response
Identify the cause of the error and repeat the IMPL or execute bs2init 0 and bs2init 1.
IOD3000
IO-CONFIGURATION ERROR: DEV#/MN xxxx/yyyy NOT UNIQUE
Meaning
The device with the device number xxx and the mnemonic yyyy is configured both as a bus
and as a channel device. The bus device has been deactivated, only the channel device can
be operated from BS2000.
Response
Reconfigure the bus device with a new mnemonic and a different unit address in X2000.