Fujitsu Siemens Computers SX series User Manual page 141

Sx150 business server
Table of Contents

Advertisement

Remote operation via PC
Wherever possible Java Web Start always loads the application from the cache and at
the same time performs a background check on the server for updates. If there are
updates, the user is informed in a window and the update is automatically loaded at the
time of the next start.
i
3. Start of PRIMEPOWER ServerView as installed PC application via the start menu or
via a desktop icon
After you have input the URL of PRIMEPOWER ServerView on the SMC or the server
and the port number 8883 in the format
http://<server-name>:8883, i.e. for example http://bari1:8883
the installation program can also be installed onto the PC for a Win32 application of
PRIMEPOWER ServerView. The self-extracting files install themselves without further
user input. After the installation program has run you can start the application via Start
-> Programs -> PRIMEPOWER ServerView Suite -> PRIMEPOWER ServerView Suite, or
create an icon for the start of PRIMEPOWER ServerView on your desktop.
As of Version 2.2A10 a version-dependent dynamic loading function of the applications
of the graphical user interface is offered (e.g. Bs2Devices). This loading function works
correctly only if PRIMEPOWER ServerView Suite Version Ï 2.2A10 is installed on the
server addressed.
When the PRIMEPOWER ServerView Suite is started the versions of the applications
loaded on the PC are compared with those on the server addressed (SMC or partition)
and, if required, applications which are not yet present are loaded (installed). In this
case a box with the following text appears:
"There are further applications available on the server. It is recommended to install them on your
client now. Please restart the user interface afterwards!"
To load click on Install. PRIMEPOWER ServerView loads the new applications and
terminates. The new applications are available after you have restarted PRIMEPOWER
ServerView.
i
If it is not possible to start an application which you have loaded on your PC, deinstall
the PRIMEPOWER ServerView Suite on the PC using the menu Start -> Programs ->
PRIMEPOWER ServerView Suite -> Uninstall PRIMEPOWER ServerView Suite and delete
the installation directory (with the standard installation this is the directory
C:\Program Files/Fujitsu Siemens Computers/WebSysAdmin).
U41272-J-Z385-3-76
You will find more information on operating PRIMEPOWER ServerView in
the manual
"PRIMEPOWER ServerView Suite V2.2
tration within a
Domain" [5].
Details on operating the PRIMEPOWER ServerView Suite are provided in the
manual
"PRIMEPOWER ServerView Suite V2.2
a
Domain" [5].
Configuration and operation
System Adminis-
System Administration within
141

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents