Offline PSR
e) Start PSR off-line with the following command:
PSR on SX servers with SMC
Prerequisites:
Procedure:
1. Prepare the SMC in the on-line mode. The SMC must be modified in the PSR menu
Prepare off-line PSR for the off-line mode. For the procedure, see the PRIMEPOWER
ServerView on-line help.
2. Change to the off-line mode:
In the off-line mode, PSR is operated via the console. The system must first be run
down to such an extent that it is in the OBP. This can be achieved in the current system
with the following command:
init 0
When the OBP prompt (ok) appears, enter:
boot obp-net -s
The system is now booted to the single-user mode via the network. If the system prompt
(#) appears, the enter the following:
/mnt/psr
The procedure first requests the root password of the SMC required for operating the
DAT disk drive, sets the TERM variable for the SUN console after a further query, then
calls PSR. PSR logs on with the basic menu.
276
/tmp/psr
The procedure first sets the TERM variable for the SUN console, then calls PSR.
PSR logs on with the basic menu.
A correctly installed SMC, with built-in DAT disk drive, is required for
the off-line mode.