Global X2000 functions
The following abnormal statuses are also reported:
–
disconnected or permission denied
It is not possible to communicate with the BS200 system on the X2000 level.
Possible causes:
–
–
–
Action:
Rectify the problem. If required, beforehand remove the BS2000 system from the
Switched nodes list, trace and remove the fault and then add the system to the list again.
–
device not configured
There is no MTC device tape-mn for the BS2000 system.
Result:
The BS2000 system is ignored in the Switched nodes list.
–
daemon stopped
There is no daemon process running in X2000 of the BS2000 system.
Result:
During subsequent operation, a new daemon process is automatically started where
required.
–
device not accessible
The X2000 path does not point to a valid device node.
Possible cause:
The physical device connection was changed after creation of the BS2000 device.
Action:
Rectify the problem. If required, beforehand remove the BS2000 system from the
Switched nodes list, trace and remove the fault and then add the system to the list again.
–
HBA removed
The X2000 path does not represent a valid device node.
Possible cause:
The host bus adapter to which the MTC device is connected was removed from the
system's partition.
Result:
The BS2000 system is ignored in the Switched nodes list.
U41272-J-Z385-3-76
X2000 is not able to respond within a set time period.
The network connection to the host is defective.
Authorization to administer the system via the PRIMEPOWER ServerView Domain
Service cannot be verified.
Magnetic tape cartridge devices
241