Global X2000 functions
The following abnormal statuses are also reported:
disconnected or permission denied
It is not possible to communicate with the BS200 system on the X2000 level.
Possible causes:
Action:
Rectify the problem. If required, beforehand remove the BS2000 system from the
Switched nodes list, trace and remove the fault and then add the system to the list again.
device not configured
There is no MTC device tape-mn for the BS2000 system.
Result:
The BS2000 system is ignored in the Switched nodes list.
daemon stopped
There is no daemon process running in X2000 of the BS2000 system.
Result:
During subsequent operation, a new daemon process is automatically started where
required.
device not accessible
The X2000 path does not point to a valid device node.
Possible cause:
The physical device connection was changed after creation of the BS2000 device.
Action:
Rectify the problem. If required, beforehand remove the BS2000 system from the
Switched nodes list, trace and remove the fault and then add the system to the list again.
HBA removed
The X2000 path does not represent a valid device node.
Possible cause:
The host bus adapter to which the MTC device is connected was removed from the
system's partition.
Result:
The BS2000 system is ignored in the Switched nodes list.
U41272-J-Z385-3-76
X2000 is not able to respond within a set time period.
The network connection to the host is defective.
Authorization to administer the system via the PRIMEPOWER ServerView Domain
Service cannot be verified.
Magnetic tape cartridge devices
241