Dynamic Reconfiguration
Canceling the DR lock
In special situations (e.g. in the event of an abnormal shutdown procedure or SETS)
BS2000/VM2000 sets a DR lock so that a SLED can be executed after shutdown.
If the lock is set, DR aborts in the preadd/preremove phase with the following message:
Current BS2000 state does not allow DR
If for example a SLED is to be executed, the lock can be canceled with the following
command:
$SMAWL_BIN/bs2dr -reset
Aborting DR
A DR process can be aborted by the user with the following command:
/opt/FJSVhwr/sbin/drc -abort
!
U41272-J-Z385-3-76
Important notes
You should avoid aborting the
terminal connection, etc.) since it can leave the system in a status which can only
be canceled using POWER-OFF/ON.
Entering [Ctrl]+[C] aborts the
effects as other signals.
(SMAWL_BIN=/opt/SMAW/X2000/bin)
command by a signal (kill, termination of the
drc
command, but can have the same negative
drc
Performing DR