Functions of the System Console Software (SCS)
Switching partitions on
The function Partition Power-On Instruction switches on one or more partitions.
i
1. Select the function Partition Power-On Instruction from the menu System/Partition Power
Administration:
3 <RETURN>
The following screen output shows the status of the individual partitions on the selected
server.
Example
machine0 System-Specific Administration
Partition Power-On Instruction
PID
--
00
01
02
Select the partitions to be powered on. (a:
To specify multiple PIDs, separate with a comma (,).
q:Quit
-------------------------------------------------------------
Select.(n,a,q,b,t,h):
In this example, the partitions of the server machine0 with the PIDs 01 and 02
(PID = Partition ID) are switched off.
2. To switch the partitions on, enter the PID(s), separated by a comma.
Example
1,2 <RETURN>
Entering a <RETURN> has the same effect in this example.
If a partition has already been activated, the command for this partition is ignored.
64
Switching on a partition starts the operating system in the partition.
Power status
---
ON
OFF
OFF
b:Back to previous menu
Functions of the System Management Console
All)
t:Go to top menu
h:Help
U41272-J-Z385-3-76