Parameter
P3.14.3
Brake Opening Frequency Limit
P3.14.4
Brake Closing Frequency Limit
P3.14.5
Brake Current Limit
P3.14.6
Brake Fault Delay
P3.14.7
Response to Brake Fault
P3.14.8
Brake Feedback

4.5.15 Group 3.15: Encoders

Table 83: Encoder Parameters
Index
Parameter
P3.15.2
Encoder Repeat Channel
P3.15.3
Encoder Advanced Control Word
M3.15.4
Channel A
M3.15.5
Channel B
Table 84: Channel A Settings
Index
Parameter
P3.15.4.1
Input Control
P3.15.4.2
Input AB Swap
76 | Danfoss A/S © 2021.09
Min
Max
Unit
Default
0
P3.3.1.2
Hz
2.00
0
P3.3.1.2
Hz
2.00
0.0
Varies
A
0.0
0.00
60.00
s
2.00
0
3
0
DigIN Slot0.1
Min
Max
Unit
De-
fault
0
1
0
0
Min
Max
Unit
0
255
0
1
ID
Description
1535
1539
1085
352
1316
0 = No action
1 = Alarm
2 = Fault (Stop according to stop
mode)
3 = Fault (Stop by coasting)
1210
ID
Description
3001
0 = Channel A
1 = Channel B
3003
b0 = Encoder A fallback during error time-
out
b1 = Encoder A no action with fallback
b2 = Encoder A fault rather than fallback
during startup
See
Table
84.
See
Table
85.
De-
ID
Description
fault
0
3010
1 = Input A: Single Ended Signaling
2 = Input A: Active Low Signaling
4 = Input B: Single Ended Signaling
8 = Input B: Active Low Signaling
16 = Input Z: Single Ended Signaling
32 = Input Z: Active Low Signaling
64 = Input M: Single Ended Signal-
ing
128 = Input M: Active Low Signaling
0
3011
0 = No
1 = Yes
AB319735759636en-000101 / DPD01822