VACON® 3000
Application Guide
The value is shown in hexadecimal format.
6.51 (ID 862) Fieldbus General Status Word
Location in the menu:
INU application: V2.8.6
AFE application: V2.8.6
BCU application: V2.5.5
This monitoring value shows the fieldbus general status word value.
The value is shown in hexadecimal format.
6.52 (ID 864) FB Status Word
Location in the menu:
INU application: V2.8.2
AFE application: V2.8.2
BCU application: V2.5.2
This monitoring value shows the status of the fieldbus status word that the application uses in bypass mode. Depending on the
fieldbus type or profile, the data can be modified before it is sent to the fieldbus.
Bit
Value = 0 (FALSE)
Bit 0
Not ready to operate
Bit 1
Not running
Bit 2
Running in the Forward direction
Bit 3
No fault
Bit 4
No alarm
Bit 5
Requested speed not reached
Bit 6
Actual speed of the drive not zero
Bit 7
Motor not magnetized (flux not ready)
Bit 8
No action
Bit 9
Reserved
Bit 10
Reserved
Bit 11
Reserved
Bit 12
Reserved
Bit 13
Reserved
Bit 14
Reserved
Bit 15
Reserved
6.53 (ID 865) FB Speed Actual
Location in the menu:
INU application: V2.8.4
AFE application: V2.8.4
BCU application: V2.5.3
Danfoss A/S © 2021.09
Monitoring value descriptions
Value = 1 (TRUE)
Ready to operate
Running
Running in the Reverse direction
Fault is active
Alarm is active
Running at requested speed
Actual speed of the drive is zero
Motor magnetized (flux ready)
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
AB319735759636en-000101 / DPD01822 | 143