VACON® 3000
Application Guide
7.19 (ID 120) Motor Cos Phi
Location in the menu:
•
INU application: P3.1.1.5
Find the value on the nameplate of the motor.
7.20 (ID 121) Keypad Control Reference Selection
Location in the menu:
•
INU application: P3.3.1.7
Use this parameter to select the reference source when the control place is keypad.
7.21 (ID 122) Fieldbus Control Reference Selection
Location in the menu:
•
INU application: P3.3.1.10
Use this parameter to select the reference source when the control place is Fieldbus.
The selection of the application with parameter P1.2Application gives the default value.
7.22 (ID 123) Keypad Direction
Location in the menu:
•
INU application: P3.3.1.9
Use this parameter to set the rotation direction of the motor when the control place is keypad.
7.23 (ID 126) Preset Frequency 3
Location in the menu:
•
INU application: P3.3.3.4
Use this parameter to set the preset frequency reference when the preset frequencies function is used. Select the preset frequencies
with the digital input signals.
7.24 (ID 127) Preset Frequency 4
Location in the menu:
•
INU application: P3.3.3.5
Use this parameter to set the preset frequency reference when the preset frequencies function is used. Select the preset frequencies
with the digital input signals.
7.25 (ID 128) Preset Frequency 5
Location in the menu:
•
INU application: P3.3.3.6
Use this parameter to set the preset frequency reference when the preset frequencies function is used. Select the preset frequencies
with the digital input signals.
7.26 (ID 129) Preset Frequency 6
Location in the menu:
•
INU application: P3.3.3.7
Use this parameter to set the preset frequency reference when the preset frequencies function is used. Select the preset frequencies
with the digital input signals.
7.27 (ID 130) Preset Frequency 7
Location in the menu:
•
INU application: P3.3.3.8
Use this parameter to set the preset frequency reference when the preset frequencies function is used. Select the preset frequencies
with the digital input signals.