INU application: P3.17.2.2.66
AFE application: P3.3.2.2.76
Use this parameter to invert the enclosure humidity and temperature status signals (IDs 3720–3735).
7.504 (ID 4001) Acceleration Compensation Filter TC
Location in the menu: P3.1.2.4.4
Use this parameter to set the acceleration compensation filter TC.
7.505 (ID 4003) AFE In Use?
Location in the menu: P3.1.2.5.3
Use this parameter to set the front-end type of the AC drive.
Set the parameter to 1 (Yes), if the drive has an active front end (AFE).
Set the parameter to 0 (No), if the drive has a passive front end (diode front end, DFE).
7.506 (ID 4004) Overvoltage Control Reference Selection
Location in the menu: P3.1.2.5.4
Use this parameter to set the high voltage level in closed-loop mode:
Supply voltage.
DC voltage high maximum.
Parameter DC voltage high limit.
7.507 (ID 4005) Overvoltage Control Reference
Location in the menu: P3.1.2.5.5
Use this parameter to set the reference voltage for overvoltage control.
7.508 (ID 4006) Motor Voltage Fault Limit
Location in the menu: P3.1.3.13
Use this parameter to set the motor voltage fault limit.
7.509 (ID 4007) Input Phase Fault Ripple Limit
Location in the menu:
INU application: P3.1.3.14
AFE application: P3.8.1.12
Use this parameter to set the voltage ripple limit for the input phase supervision.
7.510 (ID 4010) Torque Reference Interpolation Time
Location in the menu: P3.3.2.9
Use this parameter to set the interpolator time constant in seconds for the torque reference input. The function makes step type
changes more linear. If the parameter is set to 0, the function is not used.
7.511 (ID 4011) Torque Reference Ramp Time
Location in the menu: P3.3.2.8
Use this parameter to set the ramp time for the nominal torque step in seconds. If the parameter is set to 0, the function is not used.
7.512 (ID 4015) Torque Reference Gain
Location in the menu: P3.3.2.7
Use this parameter to set the gain for the torque reference.
7.513 (ID 4017) Flux Ready Limit
Location in the menu: P3.1.5.14