b.
Go into the Parameter backup submenu.
STOP
c.
Use the arrow buttons Up and Down to select a function. Accept the selection with the [OK] button.
STOP
The command Restore factory defaults brings back the parameter settings that were made at the factory. Use the com-
mand Save to keypad to copy all the parameters to the control panel. The command Restore from keypad copies all the
parameters from the control panel to the drive.
2.
Detach the control panel and connect it to another drive.
3.
Download the parameters to the new drive with the command Restore from keypad.

2.2.9 Comparing the Parameters

Use this function to compare the current parameter set with one of these 4 sets. See more about these parameters in
ter Backup
Parameters.
Set 1 (B6.5.4 Save to Set 1)
Set 2 (B6.5.6 Save to Set 2)
Defaults (B6.5.1 Restore Factory Defaults)
If you have not saved the parameter set with which you want to compare the current set, the display shows the text Comparing
failed.
Procedure
1.
Go into the User settings menu.
20 | Danfoss A/S © 2021.09
READY
User settings
ID:
M6.5
Language selection
English
Parameter backup
( 7 )
Drive name
Drive
READY
Parameter backup
ID:
M6.5.1
Restore factory defaults
Save to keypad
Restore from keypad
N O T I C E
Keypad
Keypad
User Interfaces
4.8.2 Parame-
AB319735759636en-000101 / DPD01822