VACON® 3000
Application Guide
Use this parameter to select the digital input signal for the breaker status 2 for enclosure temperature controls.
7.433 (ID 3638) Temperature Control Breaker Status 3
Location in the menu:
INU application: P3.17.2.2.36
AFE application: P3.3.2.2.34
Use this parameter to select the digital input signal for the breaker status 3 for enclosure temperature controls.
7.434 (ID 3639) Temperature Control Breaker Status 4
Location in the menu:
INU application: P3.17.2.2.37
AFE application: P3.3.2.2.35
Use this parameter to select the digital input signal for the breaker status 4 for enclosure temperature controls.
7.435 (ID 3640) Cabinet Heat Exchanger Status 1
Location in the menu:
INU application: P3.17.2.2.38
AFE application: P3.3.2.2.36
Use this parameter to select the digital input signal for the breaker status 1 of the enclosure heat exchanger fan.
Active = Contactor is closed.
7.436 (ID 3641) Cabinet Heat Exchanger Status 2
Location in the menu:
INU application: P3.17.2.2.39
AFE application: P3.3.2.2.37
Use this parameter to select the digital input signal for the breaker status 2 of the enclosure heat exchanger fan.
Active = Contactor is closed.
7.437 (ID 3642) Cabinet Heat Exchanger Status 3
Location in the menu:
INU application: P3.17.2.2.40
AFE application: P3.3.2.2.38
Use this parameter to select the digital input signal for the breaker status 3 of the enclosure heat exchanger fan.
Active = Contactor is closed.
7.438 (ID 3643) Cabinet Heat Exchanger Status 4
Location in the menu:
INU application: P3.17.2.2.41
AFE application: P3.3.2.2.39
Use this parameter to select the digital input signal for the breaker status 4 of the enclosure heat exchanger fan.
Active = Contactor is closed.
7.439 (ID 3644) Leak Detection System OK 1
Location in the menu:
INU application: P3.17.2.2.42
AFE application: P3.3.2.2.40
Use this parameter to select the digital input signal for the leak detection system status 1.
Active signal = System OK.
244 | Danfoss A/S © 2021.09