Fault Code 32 - Fan Cooling; Fault Code 33 - Fire Mode Enabled; Fault Code 37 - Device Changed (Same Type) - Danfoss VACON 3000 Application Manual

Table of Contents

Advertisement

VACON® 3000
Application Guide

8.2.21 Fault Code 32 - Fan Cooling

8.2.21.1 Fault Code 32, ID 311 - Fan Cooling
Cause
The fan speed does not agree to the speed reference accurately, but the drive operates correctly.
Troubleshooting
Reset the fault and restart the drive.
Clean or replace the fan.
8.2.21.2 Fault Code 32, ID 312 - Fan Cooling
Cause
The fan life time (that is, 50 000 h) is complete.
Troubleshooting
Replace the fan and reset the life time counter of the fan.

8.2.22 Fault Code 33 - Fire Mode Enabled

8.2.22.1 Fault Code 33, ID 320 - Fire Mode Enabled
Cause
The fire mode of the drive is enabled. The protections of the drive are disabled or autoreset.
Troubleshooting
Check the parameter settings and the signals.
This alarm is reset automatically when fire mode is disabled.

8.2.23 Fault Code 37 - Device Changed (Same Type)

8.2.23.1 Fault Code 37, ID 361 - Device Changed (Same Type)
Cause
The power unit was replaced by a new one that has the same size. The device is ready to be used. The parameters are available
in the drive.
Troubleshooting
Reset the fault. The drive reboots after you reset the fault.
8.2.23.2 Fault Code 37, ID 362 - Device Changed (Same Type)
Cause
The option board in slot B was replaced by a new one that you have used before in the same slot. The device is ready to be used.
Troubleshooting
Reset the fault. The drive starts to use the old parameter settings.
8.2.23.3 Fault Code 37, ID 363 - Device Changed (Same Type)
Cause
The option board in slot C was replaced by a new one that you have used before in the same slot. The device is ready to be
used.
Troubleshooting
Reset the fault. The drive starts to use the old parameter settings.