Danfoss VACON 3000 Application Manual page 139

Table of Contents

Advertisement

VACON® 3000
Application Guide
6.24 (ID 57) DIN Status Word 2
Location in the menu:
INU application: V2.6.6
AFE application: V2.6.5
BCU application: V2.4.5
This monitoring value shows the bit-coded status of the digital input signals.
The monitoring value is a 16-bit word, where each bit shows the status of 1 digital input. From each slot, 6 digital inputs are read.
Word 2 starts from the input 5 in slot C (bit0) and ends with input 6 in slot E (bit13).
6.25 (ID 59) Analog Input 1
Location in the menu:
INU application: V2.4.4
AFE application: V2.4.4
BCU application: V2.3.4
This monitoring value shows the value of the analog input signal as a percentage of the used range.
6.26 (ID 60) Analog Input 2
Location in the menu:
INU application: V2.4.5
AFE application: V2.4.5
BCU application: V2.3.5
This monitoring value shows the value of the analog input signal as a percentage of the used range.
6.27 (ID 61) Analog Input 3
Location in the menu:
INU application: V2.4.6
AFE application: V2.4.6
This monitoring value shows the value of the analog input signal as a percentage of the used range.
6.28 (ID 62) Analog Input 4
Location in the menu:
INU application: V2.4.7
AFE application: V2.4.7
This monitoring value shows the value of the analog input signal as a percentage of the used range.
6.29 (ID 68) Cos Phi Actual
Location in the menu:
Standard application: V2.6.17
This monitoring value shows the actual Cos Phi value of the motor.
6.30 (ID 73) Motor Shaft Power
Location in the menu:
Standard application: V2.3.8
This monitoring value shows the actual shaft power of the motor (calculated value). The unit of measurement is kW or hp, depend-
ing on parameter kW/hp Selection (ID 1198) value.
The number of decimals in the value of this monitoring value varies depending on the size of the AC drive. In fieldbus control, ID
15592 can be mapped as Process Data Out to determine how many decimals are used. The last significant digit tells the amount of
decimals.
Danfoss A/S © 2021.09
Monitoring value descriptions
AB319735759636en-000101 / DPD01822 | 139