VACON® 3000
Application Guide
Ref
0%
-100%
D
Illustration 23: The Joystick Function
A
AI joystick dead zone = 10%
B
Reference
7.56 (ID 386) Joystick Sleep Delay
Location in the menu:
•
INU application: P3.3.5.3
Use this parameter to set the joystick sleep delay. If the joystick reference stays in the set sleep zone for longer than the sleep delay,
the drive stops and the sleep mode is activated.
The Joystick sleep function is disabled when the value of this parameter is set to 0.
7.57 (ID 387) AI1 Signal Inversion
Location in the menu:
•
INU application: P3.5.2.1.6
•
AFE application: P3.5.2.1.6
•
BCU application: P3.4.2.1.6
Use this parameter to invert the analog input signal. When the analog input signal is inverted, the curve of the signal becomes the
opposite.
It is possible to use the analog input signal as frequency reference. The selection of the value 0 or 1 change scaling of the analog
input signal.
174 | Danfoss A/S © 2021.09
A
-10%
B
N O T I C E
C
+10%
C
Maximum Frequency
D
- Maximum Frequency
Parameter descriptions
+100%
+100%
AnIn
AB319735759636en-000101 / DPD01822