VACON® 3000
Application Guide
Index
Monitoring value
V2.10.5.2
Power on status word
V2.10.5.3
Power on state fault
V2.10.5.4
Power On status word fault
V2.10.5.5
Precharge status word fault
V2.10.5.6
Precharge Error Flags @ Fault
PreStart OK requires that all of the following status words are OK: MCB Status (ID 3570), Leak Det. Status (ID 3571), GSW UFES Status (ID 3575), and
1
LCL Status (ID 3569).
Cooling OK requires that all of the following status words are OK: Enc HX Status (ID 3572), and HEX Status (ID 3573).
2
Table 130: Interlock Monitoring Values
Index
Monitoring value
V2.10.6.1
GSW UFES Status Word
102 | Danfoss A/S © 2021.09
Unit
Scale
ID
1
3574
1
3521
1
3583
1
3514
1
3580
Unit
Scale
ID
1
3575
AFE Application
Description
4 = Cooling
5 = Charging
6 = Contactor Close
7 = Stabilizing
8 = Operational
b0 = PowerOn Req
b1 = Power Off
b2 = Reset
b3 = Run Cooling
b4 = Precharge
b5 = Power On
b6 = Fault
b7 = Precharge Ready
b8 = PreStart OK
(1)
b9 = MCBs and Interlocks OK
b10 = Leak Detection OK
b11 = LCL OK (AFE)
b12 = GSW AFR DSI OK
b13 = Cooling OK
(2)
b14 = DC Capacitors OK (INU)
b15 = Precharge Inhibit
See ID 3520.
See ID 3574.
See ID 3513.
See ID 3568 in
Table
128.
Description
b0 = GSW Open 1
b1 = GSW Open 2
b2 = GSW Open 3
b3 = GSW Open 4
b4 = GSW Not Closed 1
b5 = GSW Not Closed 2
b6 = GSW Not Closed 3
b7 = GSW Not Closed 4
b8 = UFES Not in Test 1
b9 = UFES Not in Test 2
b10 = UFES Not in Test 3
b11 = UFES Not in Test 4
b12 = AFR Online
AB319735759636en-000101 / DPD01822