Danfoss VACON 3000 Application Manual page 292

Table of Contents

Advertisement

VACON® 3000
Application Guide
8.2.28.5 Fault Code 43, ID 424 - Encoder Fault
Cause
The encoder board is missing.
Troubleshooting
Check the encoder connections.
Check the encoder and the encoder cable.
Check the encoder board.
Check the encoder frequency in open-loop mode.
8.2.28.6 Fault Code 43, ID 425 - Encoder Fault
Cause
Encoder speed deviation supervision.
Troubleshooting
Check the encoder connections.
Check the encoder and the encoder cable.
Check the encoder board.
Check the encoder frequency in open-loop mode.
Check the basic motor parameters.
8.2.28.7 Fault Code 43, ID 426 - Encoder Fault
Cause
Encoder pulse count supervision.
The estimated encoder pulse count/revolution is different from the value set by the parameter.
Troubleshooting
Check the encoder pulse count/revolution value.
Check the encoder coupling (gear ratio, friction wheel).
Check the basic motor parameters.
8.2.28.8 Fault Code 43, ID 427 - Encoder Fault
Cause
The maximum acceleration rate is exceeded.
The motor acceleration calculated from the encoder speed is higher than the actual maximum of the application.
Troubleshooting
Check the encoder channel connections.
Check the encoder board.
Check the encoder and the encoder cable.
Check the mechanical mounting of the encoder.
Check the encoder frequency in open-loop mode.
8.2.29 Fault Code 44 - Device Changed (Different Type)
8.2.29.1 Fault Code 44, ID 431 - Device Changed (Different Type)
Cause
There is a new power unit of a different type. Parameters are not available in the settings.
Troubleshooting
Reset the fault. The drive reboots after you reset the fault.
Set the power unit parameters again.
292 | Danfoss A/S © 2021.09
Fault tracing
AB319735759636en-000101 / DPD01822

Advertisement

Table of Contents
loading

Table of Contents