6
CALIBRATION
This chapter describes basic calibration procedure of the Fortus 360mc/400mc system.
AUTOMATIC CALIBRATION
After tips are changed the user menu will prompt you to perform a series of automatic calibrations: Auto Z Stage
Zero Calibration, Auto Tip-to-Tip Calibration, and XYZ Offset Calibration
Note: Perform an Autohome XYZ before initiating automatic calibration
(Operator Control > Calibrate > AutoHome XYZ).
Operator interaction is not required for Auto Z Stage Zero calibration or the Auto
Tip-to-Tip calibration.
XY and Z Tip Offset requires that the operator analyze a calibration part and
supply the system with correction values.
Note: If the Automatic Calibration fails, then the same set of calibrations must be
run manually - starting with
page
74.
AUTO Z STAGE ZERO CALIBRATION
Auto Z Stage Zero Calibration (
location on the build sheet.
No operator interaction is required.
Auto Z Stage Zero is performed as a part of the tip changing procedure and:
1.
If user placement is set to
•
Before each job build.
2.
If user placement is set to
•
At power-up.
If the user placement setting is changed to
•
•
If the oven temperature was unstable within the preceding six hours of a job build.
•
If the previous job was started when the oven temperature was unstable.
"Auto Z Stage Zero Calibration - Manual Start" on
in the display menu) sets the model liquefier tip to the Z zero
Auto Z Zero
(see
"Part Build Location" on page
YES
NO.
68
.
54).
.
YES