Load Cell Calibration - Stratasys Objet24 Operator Training Manual

Hide thumbs Also See for Objet24:
Table of Contents

Advertisement

Load Cell Calibration

• What: the Load cell are sensors that measure the weights of the cartridges and the waste container.
• Why:
• Verify the load cells are calibrated according to the material weight in the cartridges.
• To prevent a head filling error (resin not flowing properly to print heads).
• When: Every 500 hours of printing or once every six months.
• How:
1.
Run the Load Cell Calibration Wizard (Options Wizards Load Cell Calibration).
Select the desired Load Cell to calibrate → continue by following the instructions.
2.
3.
Remove the cartridge or container, as instructed by the wizard, close the drawer and click Next
4.
Observe the numbers and wait until the level is relatively stable- two units above or below the average level shown.
5.
Select the Values are stable check box, and click Next.
6.
Click Done in the final wizard screen.
24
STRATASYS / THE 3D PRINTING SOLUTIONS COMPANY

Advertisement

Table of Contents
loading

This manual is also suitable for:

Objet30Objet30 orthodeskObjet30 dental primeObjet30 proObjet30 prime

Table of Contents