FORTUS 360mc/400mc and FDM 360mc/400mc User Guide

Automatic Calibration

After tips are changed the user menu will prompt you to perform a series of
automatic calibrations: Auto Z Stage Zero Calibration, Auto Tip-to-Tip
Calibration, and XYZ Offset Calibration
Note: Perform an Autohome XYZ before initiating automatic
calibration (Operator Control > Calibrate > AutoHome XYZ).
Operator interaction is not required for Auto Z Stage Zero
calibration or the Auto Tip-to-Tip calibration.
XY and Z Tip Offset requires that the operator analyze a
calibration part and supply the system with correction values.
Note: If the Automatic Calibration fails, then the same set of
calibrations must be run manually - starting with
Stage Zero Calibration - Manual Start" on

Auto Z Stage Zero Calibration

Auto Z Stage Zero Calibration (
model liquefier tip to the Z zero location on the build sheet.
No operator interaction is required.
Auto Z Stage Zero is performed as a part of the tip changing procedure and:
1.
If user placement is set to
• Before each job build.
2.
If user placement is set to
• At power-up.
• If the user placement setting is changed to
• If the oven temperature was unstable within the preceding six
hours of a job build.
• If the previous job was started when the oven temperature was
unstable.
in the display menu) sets the
Auto Z Zero
("Part Build Location" on
YES
NO
Chapter 6

Calibration

"Auto Z
page 6-8.
page 4-30)
.
YES
6-1