Clean the Tip Sensor Plunger

1.
Remove the plunger - gently pull up and out.
2.
Remove material residue on the top of the plunger with a razor blade.
3.
Replace the plunger in the sensor bracket - make sure the flat surface is up.

As Needed Maintenance

Upgrading Software or Entering a System Code

Upgrades to controller software and system codes are uploaded to the system.
Note: To upgrade system controller software, or to enter a
system change code, access to an Insight workstation is
required.
An Insight workstation with Internet access will check for
controller software upgrades, notify you of upgrade
availability, and walk you through the procedure to download
the upgrade to the Insight workstation.
System change codes are obtained from your Stratasys
Representative.
1.
Verify that the system is idle.
2.
Place the system in the Receive Software Upgrade or Code mode.
A.
Figure 7-7: Tip Sensor
From the Main Menu select
Build Job..
Operator Control..
Modeler Status..
>Maintenance..
(Figure
Tip Sensor Plunger
and press ENTER.
Maintenance
| *Tips: Model T16
| *
Support T16
7-9
7-7)