Clean The Tip Sensor Plunger - Stratasys FORTUS 360mc Manual

Hide thumbs Also See for FORTUS 360mc:
Table of Contents

Advertisement

FORTUS 360mc/400mc and FDM 360mc/400mc User Guide

Clean the Tip Sensor Plunger

1.
Remove the plunger - gently pull up and out
2.
Remove material residue on the top of the plunger with a razor blade.
3.
Replace the plunger in the sensor bracket - make sure the flat surface is
up.
Figure 7-7: Tip Sensor
(Figure
7-7).
Tip Sensor Plunger