Clean The Tip Sensor Plunger; As Needed Maintenance; Upgrading Software Or Entering A System Code - Stratasys Fortus 360mc User Manual

3d production system
Hide thumbs Also See for Fortus 360mc:
Table of Contents

Advertisement

CLEAN THE TIP SENSOR PLUNGER

1.
Remove the plunger - gently pull up and out.
2.
Remove material residue on the top of the plunger with a razor blade.
3.
Replace the plunger in the sensor bracket - make sure the flat surface is up.
Figure 7-7:
Tip Sensor

AS NEEDED MAINTENANCE

UPGRADING SOFTWARE OR ENTERING A SYSTEM CODE

Upgrades to controller software and system codes are uploaded to the system.
Note: To upgrade system controller software, or to enter a system change code,
access to an Insight workstation is required.
An Insight workstation with Internet access will check for controller software
upgrades, notify you of upgrade availability, and walk you through the procedure
to download the upgrade to the Insight workstation.
System change codes are obtained from your Stratasys Representative.
1.
Verify that the system is idle.
2.
Place the system in the Receive Software Upgrade or Code mode.
A.
From the Main Menu select
Maintenance
Build Job..
Operator Control..
Modeler Status..
>Maintenance..
(Figure
7-7)
Tip Sensor Plunger
and press ENTER.
| *Tips: Model T16
| *
Support T16
84