YASKAWA MP2100 Series User Manual page 286

Machine controller design and maintenance
Table of Contents

Advertisement

(4) Related Parameters
(a) Setting Parameters
Parameter
Name
OB
000
Servo ON
OB
013
Speed Loop P/PI
Switch
OW
03
Function 1
OW
08
Motion Command
OB
090
Command Pause
OB
091
Command Abort
OL
10
Speed Reference
OL
14
Positive Side Limit-
ing Torque Setting at
the Speed
Reference
OL
18
Speed Override
OL
36
Linear Acceleration
Time
OL
38
Linear Deceleration
Time
OW
3A
S-Curve Accelera-
tion Time
(b) Monitoring Parameters
Parameter
Name
IB
001
Servo ON
IL
02
Warning
IL
04
Alarm
IW
08
Servo Command
Type Response
IB
090
Command Executing
IB
091
Hold Completed
IB
093
Command Error End
IB
098
Command
Completed
IB
0C0
Distribution
Completed
Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor, 0: Power OFF to Servomotor
Motor will start to rotate when this bit is set to 1 under the speed control data
mode.
Switch the speed control loop between PI control and P control.
0: PI control, 1: P control
Set the speed unit, acceleration/deceleration unit, and filter type.
The mode is changed to speed control mode when this parameter is set to 23.
This parameter is ignored for VELO command.
The axis will decelerate to a stop if this bit is set to 1 during operation.
Specify the speed. This setting can be changed during operation. The unit
depends on the setting of OW
Set the torque limit for the speed reference. The same value is used for both the
positive and negative directions.
This parameter allows the motor speed to be changed without changing the Speed
Reference (OL
10). Set the speed as a percentage of the Speed Reference
Setting. This setting can be changed during operation.
Setting range: 0 to 32767 (0% to 327.67%) Setting unit: 1 = 0.01%
Example: Setting for 50%: 5000
Set the rate of acceleration or acceleration time constant for operation.
Set the rate of deceleration or deceleration time constant for operation.
Set the acceleration/deceleration filter time constant. Exponential acceleration/
deceleration or a moving average filter can be selected in OW
Change the setting only after pulse distribution has been completed for the
command (IB
0C0 is ON).
Monitor Contents
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
Stores the most current warning.
Stores the most current alarm.
Indicates the motion command that is being executed.
The response code will be 23 during VELO command execution.
Turns ON when abort processing is being performed for VELO command. Turns
OFF when abort processing has been completed.
Always OFF for VELO command.
Turns ON if an error occurs during VELO command execution. The axis will
decelerate to a stop if it is operating. Turns OFF when another command is
executed.
Always OFF for VELO command.
Turns ON when pulse distribution has been completed for the move command.
Turns OFF during execution of a move command.
8.23 Speed Reference (VELO)
Setting
03.
03.
8
8-77