YASKAWA MP2100 Series User Manual page 366

Machine controller design and maintenance
Table of Contents

Advertisement

(b) Related Parameters
• Setting Parameters
Parameter
Name
OB
000
Servo ON
OW
03
Function 1
OW
08
Motion Command
OB
095
Position Reference
Type
OL
1C
Position Reference
Type
OW
3A
S-Curve Acceleration
Time
• Monitoring Parameters
Parameter
Name
IB
001
Servo ON
IL
02
Warning
IL
04
Alarm
IW
08
Servo Command Type
Response
IB
090
Command Executing
IB
091
Command Hold
Completed
IB
093
Command Error End
IB
098
Command Execution
Completed
IB
0C0
Distribution Completed
IB
0C1
Positioning Completed
IB
0C3
Position Proximity
Turn the power to the Servomotor ON and OFF.
1: Power ON to Servomotor, 0: Power OFF to Servomotor
Set this bit to 1 before setting the Motion Command (OW
Set the speed unit, acceleration/deceleration unit, and filter type.
The positioning starts when this parameter is set to 6.
Switch the type of position reference.
0: Incremental addition mode, 1: Absolute mode
Set this parameter before setting the Motion Command (OW
Set the target position for positioning. The setting can be changed every high-
speed scan.
Set the acceleration/deceleration filter time constant. Exponential
acceleration/deceleration or a moving average filter can be selected in
OW
03.
Change the setting only after pulse distribution has been completed for the
command (IB
0C0 is ON).
Monitor Contents
Indicates the Servo ON status.
ON: Power supplied to Servomotor, OFF: Power not supplied to Servomotor
Stores the most current warning.
Stores the most current alarm.
Indicates motion command during execution.
The response code is 6 during LATCH operation.
Always OFF for LATCH operation.
Always OFF for LATCH operation.
Turns ON if an error occurs during LATCH operation. The axis will decelerate
to a stop if it is moving. Turns OFF when another command is executed.
Always OFF for LATCH operation.
Turns ON when distribution has been completed for the move command.
Turns OFF during execution of a move command.
Turns ON when pulse distribution has been completed. OFF in all other cases.
Turns ON when Distribution Completed (DEN) turns ON.
11.3 Motion Commands
Setting
08) to 6.
08) to 6.
11
11-27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Japmc-mc2100Mp2100m seriesJapmc-mc2140

Table of Contents