3 System Startup
3.1.8 Initializing the System
(3) Operation Procedure
Operation Keys
(4) Turning ON the Power Supply Again
Parameter settings will be initialized but some of the parameters need the power to be cycled to enable the set-
tings. Always turn the power OFF and then back ON.
3-12
Display Example
BB
- FUNCTION -
F n 0 0 4
F n 0 0 5
F n 0 0 6
F n 0 0 7
BB
P a r a m e t e r I n i t
S t a r t :
[ D A T A ]
R e t u r n : [ S E T ]
BB
P a r a m e t e r I n i t
S t a r t :
[ D A T A ]
R e t u r n : [ S E T ]
Description
Press the
Key to display the Utility Function
Mode main menu, then press the
and select Fn005.
Press the
Key.
The display is switched to the execution display of
Fn005 (parameter initialization).
• If the display is not switched and "NO-OP" is dis-
played in the status display, the Write Prohibited Set-
ting (Fn010 = 0001) is set. Check the setting and reset.
Press the
Key to initialize the parameters.
"Parameter Init" will blink during initialization. When
initialization has been completed, "Parameter Init" will
stop blinking and the status display will change as
shown below.
BB → Done → A.941
Note: A.941 is a warning that a parameter that needs the
power to be cycled has been changed.
• Press the
Key if you do not want to initialize
parameters. The display will return to the Utility
Function Mode main menu.
Keys