Switch Settings - YASKAWA MP2100 Series User Manual

Machine controller design and maintenance
Table of Contents

Advertisement

4 Specifications

4.4.3 Switch Settings

4.4.3 Switch Settings
Use these switches to set the operating conditions for the MP2100M when the power is turned ON.
(1) Mode Switch 1 (S1)
No.
Name
1
TEST
2
MON
3
CNFG
4
INIT
5
SUP
6
STOP
7
SLOT0
8
SLOT1
* Set the CP number allocated to the communication process logic port. When using two or more
MP2100M, set a different CP number for each MP2100M.
(2) Reset Switch
This switch resets the MP2100M. This switch can be used to turn ON and OFF the MP2100M power without
turning the host computer ON and OFF.
4-10
Mode switch 1 (S1)
Status
Function
ON
System use
OFF
Normal operation
ON
System use
OFF
Normal operation
ON
Configuration mode
OFF
Normal operation
ON
Memory clear
OFF
Normal operation
ON
System use
OFF
Normal operation
ON
User program stopped
OFF
User program running
SLOT
- SLOT0
 
1
- ON
CP4
ON
- OFF
CP3
ON
- ON
CP2
OFF
- OFF
CP1
OFF
Reset switch
Factory
Setting
OFF
Always leave set to OFF.
OFF
Always leave set to OFF.
OFF
Set to ON to execute self-configuration for the
connected devices.
OFF
Set to ON to clear memory. If this switch is set
to OFF, the program stored in flash memory
will be executed. The S registers and M regis-
ters are cleared to 0.
OFF
Always leave set to OFF.
OFF
Set to ON to stop the user program executing
and perform program debugging.
OFF
Use to set CP number.
OFF
Details