10 Absolute Position Detection
10.3.2 Infinite Length Axis
The following programming example (ladder program) is for the flowchart shown above.
The axis used here is axis 1 of module 1. Change the motion parameter register number if the module and axis
numbers are different.
Continues on next page.
10-26
H11
ABS System Infinite Length Mode Axis: Axis No. 1
First address in the toggle buffer: MW30000
$FSCAN-H (ON for just one scan after high-speed scan starts)
SB000001
Servo Power Supply Turned Back ON Signal
IB0000E
First scan or Servo Power Supply Turned Back ON Signal
MB300005
IFON
Toggle Buffer Enabled Flag
MB300000
IFON
$ONCOIL
SB000004
ELSE
$ONCOIL
SB000004
IEND
IEND
SVRDY (Motion Controller Run Ready)
IB80000
IFON
Position Data Re-setup Request Flag
MB300002
IFON
ABS System Infinite Length Position Control Information Load Completed Flag
IB800C8
IFON
Toggle Buffer Selection Flag
MB300001
IFON
MB300005
Position Data Re-setup Request Flag ON
MB300002
Position Data Re-setup Request Flag OFF
MB300002