(2) Motion Error Type 2
The specific motion alarms for the MP2100/MP2100M is shown below.
Warning (IL
Alarm (IL
Servo Alarm Code
(IW
02)
04)
2D)
Bit 1: Setting Parameter Error
Bit 2: Fixed Parameter Error
Over Range Parameter Number (IW
Bit 0: Excessively Following Error
Bit 3: Servo Driver Error
Bit 4: Motion Command Setting Error
Bit 0: Servo Driver Error
Bit 1: Positive Overtravel
Bit 2: Negative Overtravel
Bit 3: Positive Soft Limit
Bit 4: Negative Soft Limit
Bit 5: Servo OFF
・
・
Bit 18: Servo Driver Command Timeout
Bit 19: Absolute Encoder Number of Turns
Exceeded
00: Absolute Data Error
02: Parameter Corrupted
10: Overcurrent
11: Ground Fault
・
・
F3: Momentary Power Loss
13.3 Motion Errors
01)
13
13-19