YASKAWA MP2100 Series User Manual page 261

Machine controller design and maintenance
Table of Contents

Advertisement

8 Motion Commands
(b) Monitoring Parameters
Parameter
IL
02
IL
04
IW
08
IB
090
IB
091
IB
093
IB
098
(4) Timing Charts
(a) Normal End
(b) Error End
8-52
Name
Warning
Stores the most current warning.
Alarm
Stores the most current alarm.
Servo Command
Indicates the motion command that is being executed.
Type Response
The response code will be 11 during DCC command execution.
Command Executing
Turns ON during DCC command execution and turns OFF when execution has
been completed.
Hold Completed
Always OFF for DCC command.
Command Error End
Turns ON if an error occurs during DCC command execution. Turns OFF when
another command is executed.
Command
Turns ON when DCC command execution has been completed.
Completed
OW
08 = 11 (DCC)
IW
08 = 11 (DCC)
IB
090 (BUSY)
IB
093 (FAIL)
IB
098 (COMPLETE)
OW
08 = 11 (DCC)
IW
08 = 11 (DCC)
IB
090 (BUSY)
IB
093 (FAIL)
IB
098 (COMPLETE)
Monitor Contents