7 Motion Parameters
7.2.2 Motion Setting Parameter Details
(25) S-Curve Acceleration Time
Set the acceleration/deceleration filter time constant.
Always make sure that pulse distribution has been completed (i.e., that monitoring parameter IB
changing the time constant.
The actual machine operation depends on the settings in the SERVOPACK parameters. Refer to Appendix B.1 Parameters
Updated when a Connection is Established (MP2100/MP2100M to SERVOPACK) for details on making parameters auto-
matically effective.
Change the time constant for the filter set using the motion command Change Filter Type.
After setting the filter type to be used, change the time constant.
The overall flow for setting the filter time constant is as follows:
1. Select the filter type in Function 1 (setting parameter OW
       ↓
2. Execute the motion command Change Filter Type (CHG_FILTER).
       ↓
3. Set the S-curve Acceleration Time (setting parameter OW
       ↓
4. Execute the motion command Change Filter Time Constant.
Once the filter type is set using the motion command, the setting is held until the power is turned OFF or the filter type is
changed.
There are two types of acceleration/deceleration filter: An exponential acceleration/deceleration filter and a moving average
filter.
The following table shows the relationship with related parameters.
OW
OW
Acceleration/deceleration used
7-24
S-Curve Acceleration Time
OW
3A
No Filter
38, Bits 8 to B = 0
Step input
OW
38
36
Setting Range
0 to 5100
03, bits 8 to B).
3A).
Exponential Acceleration/Deceleration Filter
OW
38, bits 8 to B = 1
Speed
Position
Phase
Setting Unit
Default Value
0.1 ms
0C0 is ON) before
Moving Average Filter
OW
38, bits 8 to B = 2
OW
3A
OW
3A
OW
36
Torque
0
OW
3A
OW
3A
OW
38