3 System Startup
3.2.2 Operation
2. Right-click the H02 drawing in the High Scan Programs Folder and select Open – Tuning Panel.
3. The Tuning Panel Window for the H02 drawing will be displayed.
The details on the Tuning Panel Window display are shown in the following table.
No.
 Data Name
∗∗∗∗∗∗∗∗∗∗∗∗∗Common monitor∗∗∗∗∗∗∗∗∗∗∗∗∗∗
1
2
Axis 1 operation ready
3
Axis 2 operation ready
4
Axis 1 current position
5
Axis 2 current position
6
∗∗∗∗∗∗∗∗∗∗∗∗∗Common operation∗∗∗∗∗∗∗∗∗∗∗∗∗∗
7
Servo ON PB
8
Alarm reset PB
9
∗∗∗∗∗∗∗∗Manual operation and setting∗∗∗∗∗∗∗∗∗
10
Axis 1 forward JOG
11
Axis 1 reverse JOG
12
Axis 2 forward JOG
13
Axis 2 reverse JOG
14
Axis 1 forward STEP
15
Axis 1 reverse STEP
16
Axis 2 forward STEP
17
Axis 2 reverse STEP
18
Axis 1 STEP moving amount
19
Axis 2 STEP moving amount
3-36
Input position and current value.
S
Display Definition
Current Value
XXXXX
00000
ON/OFF
OFF
ON/OFF
OFF
XXXXXXXXXX
0000000000
XXXXXXXXXX
0000000000
XXXXX
00000
S
ON/OFF
OFF
S
ON/OFF
OFF
XXXXX
00000
S
ON/OFF
OFF
S
ON/OFF
OFF
S
ON/OFF
OFF
S
ON/OFF
OFF
S
ON/OFF
OFF
S
ON/OFF
OFF
S
ON/OFF
OFF
S
ON/OFF
OFF
S
XXXXXXXXXX
0000000000
S
XXXXXXXXXX
0000000000
Unit
Lower limit
Upper Limit
REG-NO.
00000
32767
DW00010
IB80000
IB80000
-
2147483647
IL8016
2147483648
-
2147483647
IL8096
2147483648
00000
32767
DW00010
MB300000
MB300001
00000
32767
DW00010
DB000010
DB000011
DB000010
DB000011
DB000012
DB000013
DB000012
DB000013
-2147483648
2147483647
DL00010
-2147483648
2147483647
DL00010
DWG
L
L
L
H02.01
H02.01
H02.02
H02.02
H02.01
H02.01
H02.02
H02.02
H02.01
H02.02