Output Signal Settings - 715 - Sony BZDM-7020 User Manual

Hide thumbs Also See for BZDM-7020:
Table of Contents

Advertisement

Output Signal Settings – 715
10-30
Chapter 10 Setup Operations
This menu controls the output signals from the DME-7000.
With the second set of soft key indications shown in the SETUP &
DIAG menu, press F5 (OUTPUT CONTROL) to display the
OUTPUT CONTROL menu.
715 OUTPUT CONTROL
Vid
Rounding Video
10 bit
Rounding Key
10 bit
Analog Signal
SMPTE
B-CAM 0
V Phase
0 H
H Phase
Vid
1.23
H Phase Fine
Fine
1.23
Blanking
Narrow
Wide
ROUNDNG
ROUNDNG
ANALOG
VIDEO
KEY
SIGNAL
OUTPUT CONTROL menu
The following are some of the operations carried out in this menu.
Setting the output video signal quantization level –
F1 (ROUNDNG VIDEO)
Press F1 (ROUNDNG VIDEO) to set the output video signal
quantization level to either 8 bits or 10 bits.
Setting the output key signal quantization level –
F2 (ROUNDNG KEY)
Press F2 (ROUNDNG KEY) to set the output key signal
quantization level to either 8 bits or 10 bits.
Key
8 bit
8 bit
B-CAM 7.5
RGB
–1 H
Key
1.23
V PHASE
BLANK-
E
G 1 2 3 4 R
ING

Advertisement

Table of Contents
loading

Table of Contents