Settings Related to Operation – 702
10-8
Chapter 10 Setup Operations
Selecting the effect of the top menu buttons – F3 (TOP
MENU BUTTON)
There are two options for the effect of the buttons in the top menu
selection section of the menu operation section, selected by
pressing F3 (TOP MENU BUTTON) as follows.
Top menu: Display the top menu in the respective menu group.
Last menu: Display the last menu accessed in the respective
menu group.
Enabling the editor interface – F4 (EDITOR IF)
To control the DME-7000 from an editor connected to the
EDITOR connector on the rear panel of the processor, press F4
(EDITOR IF), to select "DME protocol" or "VTR protocol".
DME protocol: for control from a BVE-9100
VTR protocol: for control from a BVE-910
Set the device constants for the intelligent device controller
connected to the editor according to the protocol used, as shown in
the following table.
DME protocol
VTR protocol
525-line
systems
625-line
systems
Enabling GPI input – F5 (GPI IF)
To activate the DME-7000 by means of trigger signals input from
external equipment connected to the GPI connector on the rear
panel of the processor, press F5 (GPI IF), to select "Enable".
For details of the trigger types and the operations which they
cause, see the section "Setting Up the GPI Inputs" (page 10-13).
CONST-1:
01 40 00 00 06 00 07 06
CONST-1:
D0 02 00 96 03 03 02 81
CONST-2:
0A 02 FF 00 00 0A FF
CONST-1:
D1 02 00 7D 03 03 02 81
CONST-2:
0A 02 FF 00 00 0A FF