Setting Light Exposure Time Control Mode - Omron ZW-XC7 User Manual

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting Light Exposure Time Control Mode

Set the amount of emitted light (maximum/minimum), amount of emitted light (fixed), and control edge.
Item
Setting item
Exposure time
Exposure control
mode
Amount of
emitted light
(maximum)
Amount of
emitted light
(minimum)
Amount of
emitted light
(fixed)
Control edge
 Explorer pane
→ Edit pane
→ Sensing settings window : [Measurement area 1]
1
Select the light exposure control mode from
[Light exposure control mode].
2
Set [Amount of emitted light] and [Control
edge].
Note
• In the sensing monitor window, you can check whether the waveform of received light is obtained correctly as set
up.
Displaying Measured Values and Received Light Waveform p.142
• The amount of emitted light cannot be exactly same as setting value [%] and actual control value [%] due to the
control resolution difference of Sensor Controller (0.1[μs]). The minimum value of control resolution is 0.1[μs ].
102
Setting Sensing
Setting value
Auto (default value)
Manual
0.01 to 100.00 (default value) [%]
0.01 (default value) to 100.00 [%]
0.01 to 100.00 (default value) [%]
1 surface/2 surfaces/3 surfaces/
4 surfaces/Peak (default value)
: [Bank] | [(Bank Data Name)] (double click)
: [Sensing setting] icon (
Description
Automatically sets the amount of emitted light within the
range that does not exceed the specified upper limit.
Usually, select this setting.
Select this mode when you want to specify the amount of
emitted light, and set the amount of emitted light (fixed
value).
When [Auto] is selected for light exposure control mode, set
the upper limit value for the amount of emitted light. The
amount of emitted light is set on the assumption that
([Measurement cycle]-3) μs is taken as 100%.
When [Auto] is selected for light exposure control mode, set
the lower limit value for the amount of emitted light. The
amount of emitted light is set on the assumption that
([Measurement cycle]-3) μs is taken as 100%.
When [Fixed] is selected for light exposure control mode,
set the fixed value for the amount of emitted light. The
amount of emitted light is set on the assumption that
([Measurement cycle]-3) μs is taken as 100%.
Select the measurement surface target for light adjustment.
Use this setting for multiple measurement surfaces.
The peak is the surface of all measurement surfaces having
the highest received light amount.
)
ZW-7000 User's Manual