Cable Diagram; Troubleshooting; Connection Of Melsec-F Fx Series Plc; System Condition - Mitsubishi Electric F920GOT-K Hardware Manual

Got-f900 series graphic operation terminal
Table of Contents

Advertisement

GOT-F900 SERIES (CONNECTION)
8.

Connection of MELSEC-F FX Series PLC

This chapter explains connection of the GOT-F900 Series display unit to the FX Series PLC.
Connection Procedure
This section introduces the procedure to connect the GOT-F900 to the FX Series PLC.
1.
Preparation
Item name

System Condition

System Configuration
2.
Setting
Item name
FXCPU Selection in
Direct Connection
Cautions on Use of
MELSEC-F FX Series
Setting of Connected
Equipment for GOT
3.
Others
Item name

Cable Diagram

Troubleshooting

8.1
System Condition
When connecting the FX Series PLC, check the COM port designation, the OS version of the GOT-
F900, and the applicable version of the screen creation software.
Compatibility when connecting FX Series PLC
GOT-F900
Series
F920GOT-K(5V)
F920GOT-K(24V)
F930GOT
F930GOT-K
F940GOT
F940WGOT
F940 Handy GOT
F943 Handy GOT
- "RS-232C" in the "COM port" column may not be available in some FX Series PLC. Refer to section 3.1.
- The screen creation software version corresponds to the model of the GOT-F900 Series. Refer to section 3.2.
*1 The RS-232C port for the Handy type GOT is provided inside the rear cover. As a result, environmental
protection is lost when using this port and such a connection is not practical. (The Handy GOT can be
connected as the final unit in a string of two or more GOTs.)
You can learn the connection availability as well as the version of the
GOT-F900 OS and the screen creation software.
You can select the configuration between the GOT and the FX Series
PLC and proper cables.
When FXCPU connection is selected, the GOT-F900 is automatically set
to fixed values. No setting is required in the FX Series PLC.
You can learn the restrictions in connecting the GOT to the FX Series
PLC.
Set the PLC type using the GOT or the screen creation software.
Cable diagrams for FX Series PLC/GOT connection.
Description of errors and how to fix them
COM port
Connection type
Two or more
RS-422
RS-232C 1:1
GOT units
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
$
Connection of MELSEC-F FX Series PLC 8
Description
Description
Description
OS version
of GOT-F900
Designer2
1.00
SW1-C
1.20
SW1-C
$
1.00
SW1-C
$
4.60
SW1-C
$
1.00
SW1-C
$
1.00
SW1-C
*1
1.00
SW1-C
*1
1.00
SW1-C
Reference
8.1
8.2
Reference
8.3
8.4
Reference
8.5
8.6
Version of screen creation
software
GT
GT
DU/WIN
Designer
SW5-26C
2.70
SW1-H
2.20
SW5-26C
2.70
SW1-A
2.00
SW5-F
2.50
SW1-D
2.10
SW1-D
2.10
8-1
1
2
3
4
5
6
7
8
9
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents