Measure:xmin - Agilent Technologies InfiniiVision 7000A Series Programmer's Manual

Table of Contents

Advertisement

:MEASure:XMIN

Command Syntax
:MEASure:XMIN [<source>]
<source> ::= {CHANnel<n> | FUNCtion | MATH}
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :MEASure:XMIN command installs a screen measurement and starts
an X- at- Min- Y measurement on the selected window. If the optional source
parameter is specified, the current source is modified.
:MEASure:XMIN is an alias for :MEASure:TMIN.
N O T E
Query Syntax
:MEASure:XMIN? [<source>]
The :MEASure:XMIN? query measures and returns the horizontal axis
value at which the minimum vertical value occurs. If the optional source is
specified, the current source is modified. If all channels are off, the query
returns 9.9E+37.
Return Format
<value><NL>
<value> ::= horizontal value of the minimum in NR3 format
See Also
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
(see
page
786)
"Introduction to :MEASure Commands"
":MEASure:XMAX"
on page 356
":MEASure:TMIN"
on page 718
Commands by Subsystem
on page 312
5