Timebase:range - Agilent Technologies InfiniiVision 7000A Series Programmer's Manual

Table of Contents

Advertisement

:TIMebase:RANGe

Command Syntax
:TIMebase:RANGe <range_value>
<range_value> ::= 5 ns through 500 s in NR3 format
The :TIMebase:RANGe command sets the full- scale horizontal time in
seconds for the main window. The range is 10 times the current
time- per- division setting.
Query Syntax
:TIMebase:RANGe?
The :TIMebase:RANGe query returns the current full- scale range value for
the main window.
Return Format
<range_value><NL>
<range_value> ::= 5 ns through 500 s in NR3 format
See Also
Example Code
seconds.
Example program from the start:
page 812
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
(see
page
786)
"Introduction to :TIMebase Commands"
":TIMebase:MODE"
on page 457
":TIMebase:SCALe"
on page 462
":TIMebase:WINDow:RANGe"
' TIME_RANGE - Sets the full scale horizontal time in seconds.
' range value is 10 times the time per division.
myScope.WriteString ":TIM:RANG 2e-3"
Commands by Subsystem
on page 456
on page 465
' Set the time range to 0.002
"VISA COM Example in Visual Basic"
5
The
on
459