Table 43 Service Request Enable Register (SRE) (continued)
Bit
5
4
3
2
1
0
Query Syntax
*SRE?
The *SRE? query returns the current value of the Service Request Enable
Register.
Return Format
<mask><NL>
<mask> ::= sum of all bits that are set, 0,..,255;
See Also
•
•
•
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
Name
Description
ESB
Event Status Bit
MAV
Message Available
---
---
MSG
Message
USR
User Event
TRG
Trigger
an integer in NR1 format
"Introduction to Common (*) Commands"
"*STB (Read Status Byte)"
"*CLS (Clear Status)"
When Set (1 = High = True), Enables:
Interrupts when enabled conditions in the
Standard Event Status Register (ESR) occur.
Interrupts when messages are in the Output
Queue.
(Not used.)
Interrupts when an advisory has been displayed
on the oscilloscope.
Interrupts when enabled user event conditions
occur.
Interrupts when a trigger occurs.
on page 134
on page 117
Commands by Subsystem
on page 116
5
133