Commands by Subsystem
Table 51 Operation Status Enable Register (OPEE) (continued)
Bit
5
4
3
2-0
Query Syntax
:OPEE?
The :OPEE? query returns the current value contained in the Operation
Status Enable register as an integer number.
Return Format
<value><NL>
<value> ::= integer in NR1 format.
See Also
164
Name
Description
Wait
Wait Trig
Trig
---
---
Run
Running
---
---
"Introduction to Root (:) Commands"
":AER (Arm Event Register)"
":CHANnel<n>:PROTection"
":EXTernal:PROTection"
":OPERegister[:EVENt] (Operation Status Event Register)"
":OVLenable (Overload Event Enable Register)"
":OVLRegister (Overload Event Register)"
"*STB (Read Status Byte)"
"*SRE (Service Request Enable)"
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
When Set (1 = High = True), Enables:
Event when the trigger is armed.
(Not used.)
Event when the oscilloscope is running (not
stopped).
(Not used.)
on page 141
on page 143
on page 232
on page 261